Continuous, real-time assays that directly quantify FLT3 catalytic activity — generating a full progress curve in every well for IC₅₀, mechanism, and selectivity studies.
Real-time kinetic or TRF endpoint formats
Optimized substrates and assay-ready kits
Compatible with physiological ATP and cofactors
Designed for: drug discovery, lead optimization, and mechanistic kinase research teams
FLT3 at a glance. FLT3 activity is measured continuously and directly with the PhosphoSens® AQT0794 substrate, or as an endpoint TRF readout with AQT0515, with no antibodies or coupling enzymes.
PhosphoSens-Kinetic assays directly quantify enzyme activity by continuously
monitoring substrate phosphorylation or dephosphorylation in real time,
generating a full progress curve in every well.
PhosphoSens-Red assays use europium-based time-resolved fluorescence detection
to enable robust, plate-based quantification of enzyme activity, making them
well suited for high-throughput screening workflows.
Select a kit, substrate, or enzyme above. Our team will confirm pricing, availability, and any applicable bundle discounts.
Active Recombinant Enzymes for FLT3
Wild-type and mutant forms of FLT3 for assay development, kinase profiling, and mechanistic studies.
Enzymes are supplied active and optimized for PhosphoSens® substrates.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
AQT-F12-12LG
N-GST Baculovirus / Sf9
FLT3 (F691L), ActiveSpecifications
Species: Human
Expression: Baculovirus-Insect Cells
MW: 73 kDa
Buffer: Supplied as sterile recombinant protein stored in 50mM Tris-HCl, pH 7.5, 150mM NaCl, 10mM glutathione, 0.1mM EDTA, 0.25mM DTT, 25% glycerol.
Purity/activity: For specific information on a given lot, see related technical data sheet.
Storage: Store product at -70°C. For optimal storage, aliquot target into smaller quantities after centrifugation and store at recommended temperature. For most favorable performance, avoid repeated handling and multiple freeze/thaw cycles.
Explore data and documents to support your kinase and phosphatase experiments. Download sample
data, protocols and other resources to see how our assays perform and to help you get started in your own lab.
All validation data generated using PhosphoSens® assays under recommended conditions.
Discover how continuous assay formats power deep understanding of kinase function. See how
PhosphoSens® assays guide inhibitor profiling, selectivity assessment, and
mechanistic characterization.